Chromatec TDA Thermal Desorber
加入詢問車
產品說明
New Thermal desorber from Chromatec
Powerful analytical instrumentation
Competitive
Easy to use
Easily compatible with 3rd party GC & GC-MS
2 models available:
• P/N 400-1201 Thermal desorber with 3D loader
• P/N 400-1202 Thermal desorber without 3D loader
Main features
• Operating principle – two-stage thermal desorption
• Sorbent tubes size: length 3½'' (89 mm) x O.D. ¼'' (6.4 mm) – compatible with most worldwide manufacturers
• 3D loader capacity 50 tubes – 24 hours running *
• Integrated touch screen – easy to use with any GC or GC-MS
• Inert sample path (SilcoNert® 2000 and SS 316 activity tested)
• Sample path temperature up to 350°C
• Trap heating rate up to 2000°C/min
• Electrically-cooled trap (no cooling agents)
• Leak test before desorption
* - at Run time 30 min.
• Improved design of sorbent tube sealing – automatic re-sealing in case of leak
• Moisture elimination prior to desorption
• Trap purity check mode
• Sample split and re-trapping at high concentrations (the same sample can be analyzed again)
• Desorption from the trap has reversed direction to sorption flow
• Tube conditioning is carried out by separate gas flow
• Two integrated UEPC channels for desorption and carrier gas
• Simple connection to GC inlet makes it possible to use the same inlet for liquid injection
Specifications
•Sample tube size (O.D., length), mm (inch) – 6.35 (1/4); 89
•Sorbent tube tray capacity* – 50
•Sample tube temperature, °С – from (Tamb+10) to 400
•Cold trap temperature, °С – from minus 20 to 400
•Trap heating rate – 500; 1000; 1500; 2000
•Valve temperature, °С – 150 to 350.
•Transfer line temperature, °С – 40 to 350.
•Carrier gas flow rate, ml/min – 0 to 200.
•Purge gas flow rate, ml/min – 0 to 200.
•RSD of output signal (H, A) with TD, %, max. – 2.
•Communication – Chromatec Analytic SW, Touch screen
•Dimensions (W, D, H) & Weight, max – 345, 550, 630 mm & 30 kg.
•Power supply & consumption – 220V AC, 50/60Hz, 700W.
* For the model P/N 400-1201.
Powerful analytical instrumentation
Competitive
Easy to use
Easily compatible with 3rd party GC & GC-MS
2 models available:
• P/N 400-1201 Thermal desorber with 3D loader
• P/N 400-1202 Thermal desorber without 3D loader
Main features
• Operating principle – two-stage thermal desorption
• Sorbent tubes size: length 3½'' (89 mm) x O.D. ¼'' (6.4 mm) – compatible with most worldwide manufacturers
• 3D loader capacity 50 tubes – 24 hours running *
• Integrated touch screen – easy to use with any GC or GC-MS
• Inert sample path (SilcoNert® 2000 and SS 316 activity tested)
• Sample path temperature up to 350°C
• Trap heating rate up to 2000°C/min
• Electrically-cooled trap (no cooling agents)
• Leak test before desorption
* - at Run time 30 min.
• Improved design of sorbent tube sealing – automatic re-sealing in case of leak
• Moisture elimination prior to desorption
• Trap purity check mode
• Sample split and re-trapping at high concentrations (the same sample can be analyzed again)
• Desorption from the trap has reversed direction to sorption flow
• Tube conditioning is carried out by separate gas flow
• Two integrated UEPC channels for desorption and carrier gas
• Simple connection to GC inlet makes it possible to use the same inlet for liquid injection
Specifications
•Sample tube size (O.D., length), mm (inch) – 6.35 (1/4); 89
•Sorbent tube tray capacity* – 50
•Sample tube temperature, °С – from (Tamb+10) to 400
•Cold trap temperature, °С – from minus 20 to 400
•Trap heating rate – 500; 1000; 1500; 2000
•Valve temperature, °С – 150 to 350.
•Transfer line temperature, °С – 40 to 350.
•Carrier gas flow rate, ml/min – 0 to 200.
•Purge gas flow rate, ml/min – 0 to 200.
•RSD of output signal (H, A) with TD, %, max. – 2.
•Communication – Chromatec Analytic SW, Touch screen
•Dimensions (W, D, H) & Weight, max – 345, 550, 630 mm & 30 kg.
•Power supply & consumption – 220V AC, 50/60Hz, 700W.
* For the model P/N 400-1201.