Pharma Test - Ampoule Breakpoint Tester 安瓿瓶斷點測試儀
加入詢問車
產品說明
Pharma Test Ampoule Breakpoint Tester PTBA 211E
安瓿瓶斷點測試儀
PTBA 211E安瓿斷點測試儀的設計和製造符合DIN EN ISO <9187-1 / 2:2010>標準。根據該標準,必須測試安瓿的斷點以控制空安瓿生產期間和填充過程之前的質量。
安瓿瓶斷點測試儀
PTBA 211E安瓿斷點測試儀的設計和製造符合DIN EN ISO <9187-1 / 2:2010>標準。根據該標準,必須測試安瓿的斷點以控制空安瓿生產期間和填充過程之前的質量。
Technical Specifications
Parameter | Specification |
Display | LED Display showing number of tests and breakpoint result |
Data Entry | Numerical and Functional keys |
Standard Force Range | 5.0 to approximately 300N (optional 500N) |
Accuracy | < 1N |
Resolution | 0.074N (300N model) – 0.1482N (500N model) |
Force Settings | Linear speed or linear force increase (standard setting: linear speed 10mm/Min) |
Selectable Range | 4.0 – 200 Millimeter/Minute or 5.0 – 200 N/Second |
Accuracy | < 2% force or < 0.1% speed |
Printer | Parallel Interface to connect Dot-Matrix or PCL 5 Printer |
Interface | RS232 COM port |
Calibrations | Multiple point for load cell precision using certified weights (PT-CAL15/30 and PT-CAL 50) |
Calibration Guidance | Built-in calibration procedures the digital load cell |
Adjustments | Two point adjustment – zero and 10kg |
Force Detection Reproducibility | PT-MT3 Magnetic Tablet and suitable support |
Instrument Housing | Stainless Steel (312) to meet GLP requirements |
Bench Space Requirement | L 30cm x W 30cm x H 48cm (without external printer ) |
Certification | All components certified to DIN EN ISO requirements |
CE / EMC Certification | All CE / EMC Certification provided |
Validation | All IQ & OQ documents included |
PTBA 211E 規格
Technical Specifications
Parameter | Specification |
Display | LED Display showing number of tests and breakpoint result |
Data Entry | Numerical and Functional keys |
Standard Force Range | 5.0 to approximately 300N (optional 500N) |
Accuracy | < 1N |
Resolution | 0.074N (300N model) – 0.1482N (500N model) |
Force Settings | Linear speed or linear force increase (standard setting: linear speed 10mm/Min) |
Selectable Range | 4.0 – 200 Millimeter/Minute or 5.0 – 200 N/Second |
Accuracy | < 2% force or < 0.1% speed |
Printer | Parallel Interface to connect Dot-Matrix or PCL 5 Printer |
Interface | RS232 COM port |
Calibrations | Multiple point for load cell precision using certified weights (PT-CAL15/30 and PT-CAL 50) |
Calibration Guidance | Built-in calibration procedures the digital load cell |
Adjustments | Two point adjustment – zero and 10kg |
Force Detection Reproducibility | PT-MT3 Magnetic Tablet and suitable support |
Instrument Housing | Stainless Steel (312) to meet GLP requirements |
Bench Space Requirement | L 30cm x W 30cm x H 48cm (without external printer ) |
Certification | All components certified to DIN EN ISO requirements |
CE / EMC Certification | All CE / EMC Certification provided |
Validation | All IQ & OQ documents included |